Performance
Features | Indicative response times | |||
---|---|---|---|---|
Water 0.2 m/s | Air 1 m/s | |||
t0.5 | t0.9 | t0.5 | t0.9 | |
ø8 mm | 10 s | 35 s | 95 s | 310 s |
Accuracy | Typical: < ± 0.5% FS, Maximum: < ± 1.0% FS | |||
Max. load protection tube | 100 bar |
Electrical specifications
Features | Nom. Output signal (short-circuit protected) | |
---|---|---|
4 – 20 mA | Ratiometric 10 – 90% of supply voltage | |
Supply voltage [US] polarity protected | 10 – 30 V DC | 4.75 – 8 V DC |
5 V DC (Nom.) | ||
Supply – current consumption | – | < 4 mA at 5 V DC |
Insulation resistance | > 100 MΩ at 100 V DC | > 100 MΩ at 100 V DC |
Supply voltage dependency | < ± 0.05% FS/10 V | – |
Current limitation | 30 mA | – |
Output impedance | – | < 25 Ω |
Load [RL] | RL<(US-10) / (0.02 A) ohm | RL> 5 kohm at 5 V DC |
Environmental conditions
Features | Description | |
---|---|---|
Media temperature (max. 120 °C without extension length) | -50 – 200 °C | |
Temperature on electronics(1) | -40 – 85 °C | |
Transport temperature range | -50 – 85 °C | |
EMC – Emmision | EN 61000-6-3 | |
EMC – Immunity | EN 61000-6-2 | |
Vibration stability | Sinusoidal 15.9 mm-pp, 5 – 25 Hz | – |
4 g, 25 Hz – 2 kHz | IEC 60068-2-6 | |
Random 7.5 gms, 5 Hz – 1 kHz | IEC 600868-2-34, IEC 60068-2-36 | |
Shock resistance | Shock 500 g/1 ms | IEC 60068-2-27 |
Free fall | IEC 60068-2-32 | |
Enclosure (depending on electrical connections) | See page Electrical connection |
Ordering
ToolSheep : บริการจำหน่ายเครื่องมือ เครื่องจักร และสินค้าอุตสาหกรรม ของแท้ ในราคาพิเศษ
สภาพอาจมีตำหนิในบางจุด แต่!! ไม่มีผลต่อการใช้งาน
☏ สอบถามรายละเอียดสินค้า และสั่งซื้อ
เวลาทำการ : วันจันทร์ – วันศุกร์ (เวลา 08.30 – 17.30 น.)
*นอกวันและเวลาทำการ ทางร้านจะติดต่อกลับในวันทำการถัดไป
โทร : 092-223-8984
Line ID : @toolsheep
Facebook : www.facebook.com/toolsheep/
Website : www.toolsheep.com